Actions
Bug #38403
closedThe log_data field in sys_log is too small, serialized data gets corrupted.
Status:
Closed
Priority:
Should have
Assignee:
-
Category:
Miscellaneous
Target version:
-
Start date:
2012-06-26
Due date:
% Done:
100%
Estimated time:
TYPO3 Version:
4.5
PHP Version:
5.3
Tags:
Complexity:
Is Regression:
Sprint Focus:
Description
When adding a comment for a stage change in workspaces, this comment is stored in the log_data field of the sys_log table.
This field can only hold 255 characters. It is not unlikely that a comment is longer than 255 chars. If the field would only hold a comment then the issue would not be that severe, but the field holds a serialized array with other data as well. This other data (a.g. stage id) is corrupted or lost when a long comment is entered.
Suggested fix: change the field to TEXT and also limit the amount characters that can be entered at the stage change in workspaces.
Holds for 4.5 up till 6.0.