Bug #55165
closed
Same ID of inputfields for starttime and endtime
Added by Dieter Porth over 10 years ago.
Updated over 9 years ago.
Description
Version Typo 6.1.5
If I click on the icon to define the endtime of a page, it will change only the starttime.
The reason:
The input-field of the starttime and the input-field of the endtime have the same id.
- Project changed from 1250 to TYPO3 Core
Dieter Porth wrote:
Version Typo 6.1.5
Additional Remark
The date-field to define [pages].[lastUpdated] shows in the form the same behavior like the field for [endtime].
- Status changed from New to Needs Feedback
- TYPO3 Version set to 6.2
- Is Regression set to No
Can you try again with latest master or latest 6.2? Cannot reproduce this issue at the moment.
What OS?
I had the same behavior on Windows with a certain PHP version - uniquid was to be blamed (which doesn't always create unique IDs, and is very slow).
- Status changed from Needs Feedback to Closed
The problem with uniqid has been fixed in master and 6.2 to solve the problem you mention on Windows.